Panels
Tests grouped around a decision
Panels reduce the number of choices by combining analyses that are commonly interpreted together. You can adjust the included tests before submitting the request. Every project is quoted before work begins.
Lipid Labs Omega-3 Quality Testing Package
10 determinations and 2 calculated values on one certificate — oxidation, EPA & DHA content and environmental contaminants, tested to the GOED Voluntary Monograph V8.1. Each result is reported against the GOED limit where the monograph sets one; elsewhere the reference applied is named, or the result is reported for information.- Oxidation (§A), EPA & DHA content (§C) and environmental contaminants (§B)
- 11-page certificate of analysis — 7 results against a GOED limit; the rest name the reference applied or are reported for information
- Accredited results carry the accreditation mark; every result names the method it was run to
Most ordered
Omega-3 Potency & Purity
Best for confirming EPA and DHA content and checking oxidation without the full contaminant suite.- Fatty Acid Profile
- EPA / DHA
- Peroxide Value
- p-Anisidine
- TOTOX
- Acid Value
Oxidation & Shelf Life
Best for investigating freshness, rancidity or stability in oils and fats.- Peroxide Value
- p-Anisidine
- TOTOX
- Acid Value
Heavy Metals & Minerals
Lead, cadmium, mercury and inorganic arsenic by ICP-MS, in oils, fats and feed.- Heavy & trace metals (Pb, Cd, Hg, inorg-As)
Environmental Contaminants
Dioxins and furans, PCBs, organochlorine pesticides, PAHs and PBDEs in oils, fats and feed.- Dioxins & furans (PCDD/PCDF)
- Dioxin-like PCBs
- Marker PCBs (ICES-6 sum)
- Organochlorine pesticides
- Polycyclic aromatic hydrocarbons
- Polybrominated diphenyl ethers
Lipid Class Analysis (TLC)
Each lipid class separated by TLC — glycerides, free fatty acids, phospholipids and esters — with its own fatty acid profile.- Triglycerides
- Diglycerides
- Monoglycerides
- Free fatty acids
- Phospholipids
- Steryl esters
- Methyl esters
- Ethyl esters
Physical Testing
Capsule weight and sample weighing for oils and encapsulated products.- Capsule weight
- Sample weighing
Individual tests
Find the method or analyte you need
Search by test name, analyte, abbreviation or method code — try “DHA”, “anisidine” or “LAL-METH-03”. Filter by test family, and review the matrix, minimum sample, turnaround and accreditation status before adding a test to the request. If you would rather describe the problem than pick a method, tell us what you need to establish.
- In scopeAccredited under ISO/IEC 17025:2017, SCC file 151170 (Laboratory No. 838), valid to 2029-11-26
- AccreditedAccredited to ISO/IEC 17025:2017
- CalculatedDerived from accredited determinations on this same certificate
- By requestPerformed by Lipid Labs but not included on the current accredited scope
- Our scope of accreditation, in full
Minimum quantities and turnaround times are shown for guidance and are confirmed on your quote. 3 determinations do not publish a method code here — ask us and we will tell you what we run. Accreditation status is shown per determination in the table.
Not sure which analytes you need?
Tell us what you are trying to demonstrate and we will put the list together for you.